IET Code of Practice for In-Service Inspection and Testing: What It Is and Who Uses It

By the trainers at TTS Training Services — teaching PAT testing across the UK since 2008

IET Code of Practice 5th Edition, published 2020, guidance for in-service inspection and testing

The IET Code of Practice is the document most PAT testing in the UK is carried out against. It is published by the Institution of Engineering and Technology, its full title is the Code of Practice for In-service Inspection and Testing of Electrical Equipment, and the current version is the 5th Edition.

 The IET Code of Practice 5th Edition, the guidance UK PAT testing is carried out against

In-service means equipment already in use, as opposed to equipment being installed for the first time. This article sets out what the Code covers, where it applies, which edition is current, what legal status it holds, who it is written for, how it compares with the other guidance document in circulation, and how PAT testing training is built around it.

What Is the IET Code of Practice?

The IET Code of Practice is guidance published by the Institution of Engineering and Technology on the in-service inspection and testing of electrical equipment. It is a book, not a regulation, and it sets out how to inspect and test electrical equipment that is already in use.

The current version is the 5th Edition, published in 2020. It runs to 136 pages and carries the ISBN 978-1-78561-966-3. The Institution of Engineering and Technology is the professional engineering body that also publishes the UK wiring regulations, and the Code of Practice sits alongside that work rather than inside it.

 IET Code of Practice as a published book: publisher, full title, 5th Edition, 136 pages and ISBN

The phrase “in-service” is the part that defines the document. Fixed wiring, consumer units and the installation itself are a different subject with different guidance. The Code of Practice deals with the kettle, the extension lead, the floor polisher and the server rack: equipment that is plugged in, used, moved, and eventually worn out.

A document with that title has a defined scope, and the scope is narrower than most people assume.

What Does the IET Code of Practice Cover?

The Code covers five areas: the inspection and testing procedure, the test methods and their pass limits, the risk-based approach to deciding what gets checked and how often, record keeping, and the competence expected of the person doing the work.

  • The combined inspection and testing procedure, including the formal visual inspection that precedes any electrical test
  • Test methods and pass limits, set out measurement by measurement
  • A risk-based approach to frequency and to deciding which items need a full electrical test rather than a visual check
  • Record keeping, including what a register of results should contain
  • Competence, meaning what the person carrying out the work needs to know

What the Code does not cover is the fixed electrical installation. Wiring, distribution boards and permanently connected equipment belong to a separate standard and a separate inspection regime, and the Code of Practice does not reach them.

Coverage raises the next question, which is where the document applies at all.

Which Workplaces and Properties Does the Code Apply To?

The Code applies to all workplaces, and to some types of rented accommodation. The publisher describes it as guidance on determining whether electrical equipment is safe for continued use, applying to all workplaces and to some rented property.

 The Code's scope by equipment and by premises, from in-service items to the fixed installation

A workplace is the main case. An office, a school, a factory, a salon, a warehouse, a village hall and a construction site are all workplaces for this purpose, and the equipment in them falls inside the Code’s scope. A privately owned home occupied by the people who own it is not a workplace, and the Code’s scope does not reach it. Rented accommodation sits in between, and the duties there depend on the tenancy and the nation.

This article covers Great Britain: England, Scotland and Wales.

Which Edition of the IET Code of Practice Is Current?

The 5th Edition is current. It was published in 2020 and replaced the 4th Edition, which had been in use since 2012.

The content moved between those two editions, and some of what moved changed the vocabulary rather than the engineering. Those changes, including the shift in terminology that has caused the most confusion, are covered on our page about PAT testing regulation changes.

Knowing which edition is current raises the question most readers arrive with.

Is the IET Code of Practice a Legal Requirement?

No. The IET Code of Practice is guidance, not law. It has no statutory force in itself, and no Act or Statutory Instrument requires anyone to own it, read it or follow it.

What the Code has instead is standing. It is recognised good practice, written by the professional engineering body, and it represents the settled view of how in-service inspection and testing should be carried out. A duty-holder, the person or organisation responsible for electrical equipment at a workplace … who works to the Code is following the method the industry recognises, and that is useful evidence that the approach taken was a reasonable one.

 The IET Code of Practice as recognised good practice rather than law, and what that means both ways

The distinction matters in both directions. Departing from the Code is not an offence, because there is no offence of departing from a code of practice. Following the Code is also not a defence in itself, because the thing a duty-holder has to satisfy is the underlying legal duty, not the book. Competitor pages often describe the Code as though it were legislation. It is not, and the people who write it do not claim that it is.

If the Code is not the law, something else is.

Where Does the Legal Duty Actually Sit?

The legal duty sits in the Electricity at Work Regulations 1989. Those regulations require electrical systems to be maintained, so far as is reasonably practicable, so as to prevent danger, and they place that duty on employers, the self-employed and people in control of premises.

The Electricity at Work Regulations 1989 do not name portable appliance testing. They do not prescribe a test method, set a pass limit, or state an interval. A separate regulation within the same instrument deals with people rather than equipment: it requires that nobody is engaged in work where technical knowledge or experience is needed to prevent danger unless they have that knowledge or experience, or are supervised appropriately.

 The Electricity at Work Regulations 1989 state the outcome; the IET Code of Practice gives a method

That is the whole shape of it. The law states the outcome, and the Code of Practice describes a recognised way of reaching it. Our guide to the Electricity at Work Regulations 1989 sets out the duty in full.

A duty that names no method leaves open the question of who carries it.

Who Uses the IET Code of Practice?

The Code is written for duty-holders and for the people who carry out the work on their behalf. The publisher names its audience as duty-holders: electrical testers, managers, and buildings or maintenance staff.

In practice, five groups work to it:

  • Electrical testers, who apply the methods and limits item by item
  • Managers and buildings or maintenance managers, who decide what gets tested, how often, and by whom
  • In-house staff trained as the competent person, who test their own organisation’s equipment
  • Contractors, who test on a customer’s behalf and issue the register of results
  • Training providers, who build a syllabus around the Code’s sequence and limits

 Five groups who work to the IET Code of Practice, and the competent person standard they share

The term that runs through all five is competent person. In the Code’s terms, a competent person is somebody with the technical knowledge or experience needed for the work, or working under a level of supervision appropriate to it. It is a description of what somebody knows and can do, not a job title and not a trade. An electrician may hold it. So may a facilities assistant who has been trained.

The Code is not the only document a duty-holder can work to, and the second one sets different numbers.

What Is the Difference Between the IET Code of Practice and BS EN 50699?

Both are guidance, and they set different test limits. BS EN 50699 is a British Standard covering the recurrent testing of electrical equipment, published in the UK in March 2021, roughly six months after the 5th Edition of the Code. A British Standard is not automatically a statutory requirement, so adopting one of these documents is a decision, not an obligation.

IET Code and BS EN 50699

The practical difference is in the numbers. The table below compares the four measurements where the two documents diverge.

Measurement IET Code of Practice 5th Edition BS EN 50699
Earth continuity 0.1 Ω plus the resistance of the supply cable 0.3 Ω up to 5 m of cable, plus 0.1 Ω for each additional 7.5 m
Insulation resistance, Class I At least 1 MΩ At least 1 MΩ
Insulation resistance, Class II At least 2 MΩ At least 2 MΩ
Touch current 5 mA 0.5 mA

An organisation adopts one document and applies it consistently. Testing half an estate to one earth continuity limit and half to another produces a register that cannot be compared with itself, which is the practical reason the choice is made once rather than per job.

Whichever document an organisation adopts, somebody has to be able to apply it.

How Is PAT Testing Training Built Around the IET Code of Practice?

Training built on the Code teaches the inspection sequence, the test methods and the pass limits in the order the Code sets them out, so that the person testing is working to the recognised method rather than to a tester’s default settings.

That is how PAT Training Now courses are structured. All formats follow the IET 5th Edition. The local open course is a one-day hands-on course at more than 21 training venues across the UK, priced at £195 +VAT. The tutor-led Zoom course covers the same material live from a desk at £145 +VAT. The on-site course is delivered at a customer’s premises for a group of up to 10 at £594 +VAT. Every format ends in the same place: a UKRS-accredited Certificate of Competence, issued within 7 to 10 days, and no prior electrical experience is needed to enrol.

GET QUALIFIED

Every figure on this page starts with the certificate

One day, no electrical experience needed, and a UKRS-accredited Certificate of Competence at the end of it. Three formats, so you can pick the one that fits how you work.


O

Online · live tutor-led Zoom
The cheapest way in and the fastest payback of the three. A full day with a real tutor, no travel, no time off site. From £145 +VAT.
See the next Zoom dates →


P

In person · open day at 21+ UK venues
Hands-on with real testers and real appliances before you charge anyone for it. Best value if you are training one or two people. £195 +VAT.
Find your nearest venue →


H

In-house · we come to your site
For employers and landlords training their own people. Up to 6 learners at your premises, +£60 per extra learner (max 12), on your own equipment, with no travel charge in England and Wales.
Get an instant quote →

If you want to work to the Code rather than around it, that is what the PAT testing courses are for.

Do You Need a Copy of the IET Code of Practice to PAT Test?

No. The Code is not a licence and is not issued to individuals. A duty-holder or tester who needs the full detail buys a copy from the publisher. A trained tester works from the inspection sequence, test methods and limits covered on the course, and refers to the Code where an unusual item needs a decision.

Does Following the IET Code of Practice Make You Compliant?

No, and the reason is the distinction already drawn. Compliance is judged against the legal duty to maintain equipment so as to prevent danger, not against the Code. Working to recognised good practice is strong evidence that a reasonable approach was taken. It is not a guarantee, and no guidance document can offer one.